Skip to content
Energy systemsReading guide
Energy Field GuideEnergy models ↗Dashboard ↗

Generation · storage · delivery

Inside the energy system.

Twelve representative architectures, from the resource to the grid. Follow the equipment, the conversion process and the constraints that shape each project.

About these models

Storage shifts energy in time; the grid moves it between locations. Neither is a primary generation source. These models explain selected arrangements, with illustrative dimensions and no implied project rating or certification.

Renewables

Solar PV

Tracking rows turn sunlight into direct current. A central inverter station converts and raises the voltage for grid export.

Explore this model ↗

The arrangement

Utility-scale, single-axis tracking PV with combined DC strings and a central inverter. The open station exposes conversion hardware. Other plants use distributed string inverters. No storage is included.

Input
Sunlight incident on photovoltaic modules.
Conversion
Semiconductor cells generate DC; inverter switching and filtering produce grid-compatible AC.
Output
AC electricity through a step-up transformer and protected export connection.
Dispatch
Weather-dependent daytime generation; controls can reduce output and manage reactive power within equipment limits.
Operating constraints
Irradiance, temperature, shading, soiling, equipment availability, inverter limits and curtailment shape production.
Grid interface
DC module rating and AC export capability are different boundaries. Interconnection studies define permitted grid operation.

Development considerations

  • Assess irradiance and hourly generation against the intended load or offtake profile.
  • Investigate grading, drainage, pile support and tracker wind/hail conditions.
  • Allow for row shading, maintenance access, ecological impacts and host-community priorities.
  • Confirm interconnection capacity, transmission access and AC/DC sizing through project-specific design.

Reading the specifications

Power · MWdc / MWac
Module-side DC and inverter/export-side AC capacities are distinct; no model rating is asserted.

Energy · MWh
Electrical energy delivered over time; actual output must be integrated, not inferred from the model.

Collection

PV modules

Cells convert absorbed light into DC electricity.

How it works

Series-connected cells are protected by a framed laminate; repeated modules form an array.

Why it matters

Module condition and exposure determine the energy available to conversion equipment.

Connected equipment

String harness

Sources: U.S. Department of Energy: Solar photovoltaic system design basics

Structure

Tracker frame & torque tube

The rotating frame carries each module row.

How it works

Bearings support a continuous torque tube; a drive changes the row angle about one horizontal axis.

Why it matters

Structural alignment and stiffness matter for motion and weather loading.

Sources: U.S. Department of Energy: Solar photovoltaic system design basics

Structure

Driven piles

Piles transfer tracker loads into the ground.

How it works

The exposed row shows the supports below its rotating beam.

Why it matters

Geotechnical conditions govern foundation design and installation.

Sources: U.S. Department of Energy: Solar photovoltaic system design basics · U.S. Department of Energy: Large-scale solar siting research

Controls

Tracker drive

A motor rotates the row as the sun moves.

How it works

Plant tracking commands act through a geared drive on the torque tube. This is a mechanical control connection.

Why it matters

Tracking improves collection but introduces moving equipment to maintain.

Connected equipment

Tracker frame & torque tube

Sources: U.S. Department of Energy: Solar photovoltaic system design basics

Collection

String harness

Wiring gathers the modules into DC strings.

How it works

Series connections raise string voltage; paired conductors carry output toward the combiner.

Why it matters

Cable routing, protection and inspection affect reliability.

Connected equipment

DC combiner

Sources: U.S. Department of Energy: Solar photovoltaic system design basics

Collection

DC combiner

Multiple DC string circuits join a common feeder.

How it works

The opened enclosure shows individual protected inputs and collection buswork in this selected central-inverter layout.

Why it matters

Aggregation reduces the number of long feeder circuits.

Connected equipment

DC isolation cabinet

Sources: SMA Solar Technology: Medium Voltage Power Station

Protection

DC isolation cabinet

A disconnect separates the field feeder from conversion equipment.

How it works

Rated switching equipment provides an isolation boundary in the DC circuit.

Why it matters

Electrical maintenance needs defined isolation and verification procedures.

Connected equipment

Central inverter

Sources: SMA Solar Technology: Medium Voltage Power Station

Conversion

Central inverter

Power electronics turn DC into AC.

How it works

The open cabinet reveals DC-link capacitors, switching modules and cooling passages; controls coordinate the switching waveform.

Why it matters

Its capability constrains AC output and grid support.

Connected equipment

AC filter & bus

Sources: U.S. Department of Energy: Inverters and grid services basics · SMA Solar Technology: Medium Voltage Power Station

Conversion

AC filter & bus

Filtering conditions the inverter output.

How it works

Inductive and capacitive elements attenuate switching content before the transformer.

Why it matters

Power quality is part of the grid interface.

Connected equipment

Step-up transformer

Sources: U.S. Department of Energy: Inverters and grid services basics

Grid

Step-up transformer

The transformer raises the AC voltage.

How it works

Magnetically coupled windings connect the inverter output to the collector voltage.

Why it matters

Voltage choice affects collector losses and equipment selection.

Connected equipment

Medium-voltage switchgear

Sources: SMA Solar Technology: Medium Voltage Power Station

Protection

Medium-voltage switchgear

Protected switching connects the station to the collector.

How it works

The cabinet represents breakers and isolation for the MV circuit.

Why it matters

Fault clearing and maintenance boundaries are part of the interconnection design.

Connected equipment

Metered grid export

Sources: SMA Solar Technology: Medium Voltage Power Station

Grid

Metered grid export

This bay marks the plant electrical boundary.

How it works

Metering measures energy passing through the protected export connection.

Why it matters

Delivered MWh can differ from gross inverter production.

Sources: U.S. Energy Information Administration: Measuring electricity · SMA Solar Technology: Medium Voltage Power Station

Controls

Weather station

Sensors describe the conditions affecting the field.

How it works

An irradiance sensor and wind instruments report conditions to plant controls; the connection carries data.

Why it matters

Weather measurements support performance assessment and tracker operating decisions.

Connected equipment

Plant controller

Sources: U.S. Department of Energy: Solar photovoltaic system design basics · U.S. Department of Energy: Large-scale solar siting research

Controls

Plant controller

The controller coordinates the field and conversion station.

How it works

Control links command tracker motion and inverter operating setpoints, rather than carrying generated power.

Why it matters

Curtailment and grid-service commands require coordinated operation.

Connected equipment

Tracker drive · Central inverter

Sources: U.S. Department of Energy: Inverters and grid services basics

Site

Field access & drainage

Clear lanes separate rows and the conversion island.

How it works

The model preserves space for field servicing and shows a drainage strip beside the rows.

Why it matters

Terrain, access and stormwater shape the usable site layout.

Sources: U.S. Department of Energy: Large-scale solar siting research

Primary sources

  1. Solar photovoltaic system design basics — U.S. Department of Energy
    Checked 2026-10-11
  2. Inverters and grid services basics — U.S. Department of Energy
    Checked 2026-10-11
  3. Medium Voltage Power Station — SMA Solar Technology
    Checked 2026-10-11
  4. Large-scale solar siting research — U.S. Department of Energy
    Checked 2026-10-11
  5. Measuring electricity — U.S. Energy Information Administration
    Checked 2026-10-11

Renewables

Wind

A three-bladed rotor captures wind. The opened nacelle reveals the shafts, gearbox and generator that turn rotation into electricity.

Explore this model ↗

The arrangement

Onshore, upwind, horizontal-axis turbine with a geared drivetrain and a full power converter. Direct-drive turbines omit the gearbox. The nacelle and tower are opened and proportions compressed for inspection.

Input
Kinetic energy in moving air.
Conversion
Aerodynamic lift rotates the hub; a gearbox raises shaft speed before the generator.
Output
Conditioned AC power through a ground transformer to a collector circuit.
Dispatch
Variable output within a permitted wind-speed envelope; pitch controls extraction and yaw aligns the rotor.
Operating constraints
Wind distribution, turbulence, wake losses, mechanical loading, availability and curtailment affect delivered energy.
Grid interface
A full converter decouples generator behavior from the grid in this chosen arrangement; transformer and protection connect the collector.

Development considerations

  • Measure the wind resource, turbulence and wake interactions across the site.
  • Check foundations, blade transport, crane access and major-component replacement routes.
  • Evaluate community setbacks, sound, ecological impacts and site-specific mitigation.
  • Study grid connection, curtailment exposure and long-term operational availability.

Reading the specifications

Power · MW
Turbine electrical capability is distinct from its weather-dependent output.

Energy · MWh
Electrical energy delivered over time; actual output must be integrated, not inferred from the model.

Collection

Rotor blades

Airfoil-shaped blades turn wind into rotation.

How it works

Lift acts on three upwind blades; their swept area intercepts the wind resource.

Why it matters

Aerodynamic loads and blade condition affect production and fatigue.

Connected equipment

Rotor hub

Sources: U.S. Department of Energy: How do wind turbines work?

Controls

Pitch bearings & drives

Each blade can rotate about its own long axis.

How it works

The drives change blade angle to regulate extraction and feather the rotor; these are control connections.

Why it matters

Pitch is central to speed and load management.

Connected equipment

Rotor blades

Sources: U.S. Department of Energy: Explore a wind turbine

Drivetrain

Rotor hub

The hub joins the three blades to the shaft.

How it works

Blade-root loads and torque pass through the hub into the drivetrain.

Why it matters

It carries substantial cyclic mechanical loading.

Connected equipment

Low-speed shaft

Sources: U.S. Department of Energy: Explore a wind turbine

Drivetrain

Low-speed shaft

The main shaft transfers rotor torque.

How it works

A large slow-turning shaft delivers mechanical power to the gearbox.

Why it matters

Torque transmission requires alignment and inspection.

Connected equipment

Speed-increasing gearbox

Sources: U.S. Department of Energy: Explore a wind turbine

Structure

Main bearing

The bearing supports the main shaft.

How it works

It allows rotation while transmitting rotor loads into the nacelle bedplate.

Why it matters

Bearing condition is a major availability consideration.

Sources: U.S. Department of Energy: Explore a wind turbine

Drivetrain

Speed-increasing gearbox

Gears trade torque for rotational speed.

How it works

An exposed planetary stage shows the low-speed shaft driving a carrier, planets meshing with a fixed internal ring and the central sun driving the output shaft. It represents the mechanism within a complete gearbox.

Why it matters

Lubrication, vibration and gear condition affect reliability.

Connected equipment

High-speed shaft & brake

Sources: U.S. Department of Energy: Explore a wind turbine · National Renewable Energy Laboratory: Gearbox Modeling and Load Simulation, pp. 11–12

Drivetrain

High-speed shaft & brake

The faster shaft couples gearbox and generator.

How it works

A disc brake supplies a stopping or holding function alongside aerodynamic control.

Why it matters

The brake is not a substitute for normal pitch regulation.

Connected equipment

Generator

Sources: U.S. Department of Energy: Explore a wind turbine

Conversion

Generator

Rotation becomes electrical power.

How it works

The generator receives mechanical power from the high-speed shaft and feeds the selected full converter.

Why it matters

Electrical and thermal limits constrain operation.

Connected equipment

Full power converter

Sources: U.S. Department of Energy: Explore a wind turbine

Structure

Nacelle & bedplate

The opened enclosure exposes the drivetrain.

How it works

The bedplate supports machine loads; the lifted shell represents weather protection.

Why it matters

Service access and structural load paths shape the assembly.

Sources: U.S. Department of Energy: Explore a wind turbine

Controls

Yaw bearing & drives

The nacelle turns to face the wind.

How it works

Drive pinions act on the ring at the tower top; this is orientation control, not power conversion.

Why it matters

Alignment affects aerodynamic capture and machine loads.

Connected equipment

Nacelle & bedplate

Sources: U.S. Department of Energy: Explore a wind turbine

Structure

Tower & access

The tower raises the rotor into the wind.

How it works

A cut tubular shell exposes an access ladder and the cable route.

Why it matters

Height, transport and foundation loads are site-design decisions.

Sources: U.S. Department of Energy: Explore a wind turbine

Structure

Foundation & anchor cage

The foundation carries the turbine loads into soil.

How it works

A concrete spread footing and anchor ring are shown in a shallow section.

Why it matters

Ground conditions govern the required civil design.

Sources: U.S. Department of Energy: How do wind turbines work?

Controls

Wind instruments

Wind speed and direction are measured at the nacelle.

How it works

Instrument signals report to the controller rather than carrying power.

Why it matters

Sensing supports alignment and operating decisions.

Connected equipment

Turbine controller

Sources: U.S. Department of Energy: Explore a wind turbine

Controls

Turbine controller

Controls coordinate rotor and electrical behavior.

How it works

Commands operate pitch, yaw, braking and the converter within the selected machine logic.

Why it matters

Control and protection settings govern permitted operation.

Connected equipment

Pitch bearings & drives · Yaw bearing & drives · High-speed shaft & brake · Full power converter

Sources: U.S. Department of Energy: Explore a wind turbine

Conversion

Full power converter

Power electronics condition generator output.

How it works

In this selected architecture all generator output passes through a converter before the transformer.

Why it matters

Converter capability and cooling affect grid operation.

Connected equipment

Ground transformer

Sources: U.S. Department of Energy: How do wind turbines work?

Grid

Ground transformer

AC voltage is raised to the collector level.

How it works

A ground-mounted transformer receives conditioned turbine output.

Why it matters

Transformer placement and cabling vary among turbine designs.

Connected equipment

Collector & export

Sources: U.S. Department of Energy: How do wind turbines work?

Grid

Collector & export

Protected cables connect the turbine to the wind plant.

How it works

A switch cabinet marks the outgoing collector circuit and meter boundary.

Why it matters

Plant energy is accumulated from actual export over time.

Sources: U.S. Energy Information Administration: Measuring electricity · U.S. Department of Energy: How do wind turbines work?

Primary sources

  1. Explore a wind turbine — U.S. Department of Energy
    Checked 2026-10-11
  2. How do wind turbines work? — U.S. Department of Energy
    Checked 2026-10-11
  3. Gearbox Modeling and Load Simulation, pp. 11–12 — National Renewable Energy Laboratory
    Checked 2026-10-11
  4. Environment and wildlife — DOE WINDExchange
    Checked 2026-10-11
  5. Measuring electricity — U.S. Energy Information Administration
    Checked 2026-10-11

Renewables

Hydropower

Water released through a dam turns a submerged runner. A vertical shaft drives the generator above it, while water returns to the downstream river.

Explore this model ↗

The arrangement

Conventional impoundment hydropower with a vertical Francis unit. The dam intake section and powerhouse are opened to show the spiral case, wicket gates, runner and draft tube. The separate spillway bypasses generation; this model has no pump-back operation.

Input
Water at a higher elevation in an impounded reservoir.
Conversion
Pressure and moving water turn the Francis runner, shaft and generator.
Output
AC electricity and water discharged through the draft tube to the tailrace.
Dispatch
Reservoir releases can be scheduled within inflow, storage and water-management constraints.
Operating constraints
Available head, flow, drought, sediment, ecology, water quality and competing water uses constrain operation.
Grid interface
Generator output passes through a transformer and protected switchyard. Flexibility depends on the particular plant and water obligations.

Development considerations

  • Evaluate long-term hydrology, drought, sediment and head variation.
  • Investigate foundation geology, dam integrity and the civil works required by the site.
  • Address fish passage, environmental flows, downstream water quality and competing water uses.
  • Separate turbine MW capability from reservoir energy and seasonal inflow; assess grid connection.

Reading the specifications

Power · Head × flow
Hydraulic power depends on water flow and elevation difference; efficiency and machine limits determine electrical output.

Energy · MWh
Reservoir volume, changing head and future inflow determine available energy. This is not a pumped-storage model.

Water

Reservoir & forebay

Stored water supplies the generating intake.

How it works

The upstream water surface sits above the tailrace, providing hydraulic head.

Why it matters

Storage and inflow constrain when and how long the plant can generate.

Connected equipment

Intake & trash rack · Gated spillway · Environmental release

Sources: U.S. Department of Energy: Types of hydropower plants · U.S. Department of Energy: How hydropower works

Civil works

Dam & crest

The dam impounds water and supports the crest.

How it works

The section shows a representative gravity-dam profile; actual shape depends on site geology and loading.

Why it matters

Civil integrity and water management dominate project design.

Sources: U.S. Department of Energy: Types of hydropower plants

Water

Gated spillway

A separate route passes water without generation.

How it works

The open chute carries overflow or controlled releases downstream of the dam.

Why it matters

The spillway serves water-management needs independently of turbine operation.

Connected equipment

Tailrace

Sources: U.S. Department of Energy: Types of hydropower plants

Water

Intake & trash rack

An intake admits reservoir water to the conduit.

How it works

Bars intercept large debris before it reaches gates and the turbine waterway.

Why it matters

Debris accumulation changes losses and maintenance needs.

Connected equipment

Intake gate

Sources: U.S. Department of Energy: How hydropower works

Water

Intake gate

A gate can isolate the generating waterway.

How it works

The vertically guided gate sits upstream of the penstock in this layout.

Why it matters

Isolation enables waterway inspection and maintenance.

Connected equipment

Penstock

Sources: U.S. Department of Energy: Types of hydropower plants

Water

Penstock

The pressure conduit conveys water toward the turbine.

How it works

A descending steel conduit preserves hydraulic pressure between intake and spiral case.

Why it matters

Conduit sizing, pressure transients and losses affect design.

Connected equipment

Spiral case

Sources: U.S. Department of Energy: How hydropower works

Water

Spiral case

The casing distributes water around the runner.

How it works

The opened representation exposes the surrounding distribution passage and its inward path.

Why it matters

Even admission supports effective runner operation.

Connected equipment

Wicket gates

Sources: U.S. Department of Energy: Types of hydropower turbines

Controls

Wicket gates

An adjustable ring regulates water entering the runner.

How it works

Guide vanes meter and direct flow from the spiral case toward the fixed-blade Francis runner.

Why it matters

They govern output while working within hydraulic operating limits.

Connected equipment

Francis runner

Sources: U.S. Department of Energy: Types of hydropower turbines

Conversion

Francis runner

The submerged reaction runner extracts hydraulic energy.

How it works

Water enters around the runner and exits downward; curved blades apply torque to the vertical shaft.

Why it matters

Runner selection must suit site head and flow.

Connected equipment

Vertical shaft & bearings · Draft tube

Sources: U.S. Department of Energy: Types of hydropower turbines

Drivetrain

Vertical shaft & bearings

The runner and generator share a mechanical axis.

How it works

A vertical shaft carries torque upward; bearings support the rotating assembly.

Why it matters

Alignment and bearing condition affect availability.

Connected equipment

Hydro generator

Sources: U.S. Department of Energy: How hydropower works

Conversion

Hydro generator

The rotating machine produces electricity.

How it works

The opened top exposes a representative rotor within a stator ring above the runner.

Why it matters

Electrical loading and cooling constrain machine operation.

Connected equipment

Generator transformer

Sources: U.S. Department of Energy: How hydropower works

Water

Draft tube

A widening passage carries water away from the runner.

How it works

The passage recovers part of the remaining velocity head. Its outlet stays below the tailwater surface to keep the water column intact.

Why it matters

Tailwater level and draft-tube design affect hydraulic performance and cavitation margin.

Connected equipment

Tailrace

Sources: U.S. Department of Energy: Types of hydropower turbines · U.S. Department of Energy: Microhydropower Handbook: draft tubes, §4.1.7

Water

Tailrace

Discharged water returns downstream.

How it works

The lower water surface receives turbine flow and the separate release paths.

Why it matters

Tailwater elevation contributes to the available plant head.

Sources: U.S. Department of Energy: How hydropower works

Water

Environmental release

A bypass represents a controlled downstream release.

How it works

This separate small waterway connects the reservoir to downstream water without passing through the runner.

Why it matters

Minimum flows and ecological obligations can limit generation scheduling.

Connected equipment

Tailrace

Sources: U.S. Department of Energy: Types of hydropower plants

Grid

Generator transformer

The transformer raises generator voltage.

How it works

The electrical route leaves the powerhouse for a three-phase step-up transformer.

Why it matters

Voltage, losses and protection require project-specific design.

Connected equipment

Switchyard & export

Sources: U.S. Department of Energy: How hydropower works

Grid

Switchyard & export

The switchyard connects generation to the grid.

How it works

Buswork, insulators and switching equipment mark the export boundary.

Why it matters

Grid export requires coordinated protection and metering.

Sources: U.S. Department of Energy: How hydropower works · U.S. Energy Information Administration: Measuring electricity

Civil works

Powerhouse & service crane

The building provides equipment access and lifting space.

How it works

An open structural frame and bridge crane make the vertical generating set visible.

Why it matters

Maintenance clearances and heavy lifts influence the civil layout.

Sources: U.S. Department of Energy: Types of hydropower plants

Primary sources

  1. Types of hydropower plants — U.S. Department of Energy
    Checked 2026-10-11
  2. Types of hydropower turbines — U.S. Department of Energy
    Checked 2026-10-11
  3. How hydropower works — U.S. Department of Energy
    Checked 2026-10-11
  4. Microhydropower Handbook: draft tubes, §4.1.7 — U.S. Department of Energy
    Checked 2026-10-11
  5. Measuring electricity — U.S. Energy Information Administration
    Checked 2026-10-11

Renewables

Geothermal

Hot reservoir fluid heats a separate working fluid. That secondary fluid drives the turbine, condenses and circulates again while the cooled geothermal fluid is reinjected.

Explore this model ↗

The arrangement

Air-cooled binary-cycle plant with production and injection wells, separate vaporizer and preheater, and a closed organic working-fluid circuit. Underground distances and equipment sizes are compressed; geothermal brine never enters the turbine.

Input
Heat carried to the surface by produced geothermal fluid.
Conversion
Heat crosses exchanger walls into a secondary fluid, which vaporizes and expands through a turbine.
Output
AC electricity, rejected heat to ambient air, and cooled brine returned to the reservoir.
Dispatch
Can generate independently of sunlight and wind when reservoir, wells and equipment support operation.
Operating constraints
Resource temperature, permeability, well productivity, chemistry, cooling conditions and auxiliary power determine sustainable net output.
Grid interface
Generator output is transformed and protected before export; pumping and fan demand reduce net electricity delivered.

Development considerations

  • Confirm the resource through geological assessment and well testing; manage drilling and productivity uncertainty.
  • Investigate brine chemistry, scaling, corrosion and long-term production/reinjection response.
  • Plan induced-seismicity monitoring, environmental assessment and community engagement for the specific resource.
  • Evaluate ambient-temperature effects on air cooling, pump/fan loads, access and interconnection.

Reading the specifications

Power · MWth / MWe
Heat-transfer rate and electrical output are different quantities. Auxiliary demand separates gross generation from net export.

Energy · MWh
Electrical energy delivered over time; actual output must be integrated, not inferred from the model.

Resource

Geothermal reservoir

Hot permeable rock provides heat to circulating fluid.

How it works

Fluid moves through pores and fractures in the hot rock between separated wells. The exposed layers represent a natural hydrothermal resource, not an underground pipe loop.

Why it matters

Temperature, permeability and sustainable production require site investigation.

Connected equipment

Production well & casing

Sources: U.S. Department of Energy: Geothermal electricity generation

Resource

Production well & casing

A cased well brings hot fluid to the surface.

How it works

The cut subsurface view shows a production path from the reservoir to the wellhead.

Why it matters

Well productivity and integrity shape the project.

Connected equipment

Production pump & wellhead

Sources: U.S. Department of Energy: Geothermal electricity generation

Resource

Production pump & wellhead

The selected well uses pumping to sustain flow.

How it works

A representative downhole pump and surface valve tree support the hot-fluid circuit.

Why it matters

Pump demand and well behavior affect net electrical output.

Connected equipment

Hot brine header

Sources: Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Heat transfer

Hot brine header

A hot-fluid pipe connects the well to heat exchange.

How it works

Insulated gathering pipe carries geothermal fluid to the vaporizer without mixing it with the working fluid.

Why it matters

Pressure, temperature and chemistry guide piping design.

Connected equipment

Vaporizer

Sources: U.S. Department of Energy: Geothermal electricity generation · Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Heat transfer

Vaporizer

The secondary working fluid is vaporized by geothermal heat.

How it works

Separate passages exchange heat across metal walls; the brine then continues to the preheater.

Why it matters

Keeping fluids separate protects the turbine from geothermal chemistry.

Connected equipment

Preheater · Binary-fluid turbine

Sources: U.S. Department of Energy: Geothermal electricity generation · Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Heat transfer

Preheater

Remaining brine heat warms returning working liquid.

How it works

In the represented counterflow train, brine leaves for reinjection while working liquid continues to the vaporizer.

Why it matters

Heat recovery improves use of the available resource.

Connected equipment

Vaporizer · Reinjection pump

Sources: Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Conversion

Binary-fluid turbine

Expanding working-fluid vapor turns a shaft.

How it works

The turbine receives only secondary-fluid vapor from the vaporizer and exhausts to the condenser.

Why it matters

Fluid choice and operating temperatures determine cycle design.

Connected equipment

Generator · Air-cooled condenser

Sources: U.S. Department of Energy: Geothermal electricity generation · U.S. Energy Information Administration: Geothermal power plants

Conversion

Generator

The turbine shaft drives electricity generation.

How it works

The exposed coupling connects the turbine rotor to the generator.

Why it matters

Gross generator output precedes plant auxiliary use and electrical losses.

Connected equipment

Transformer & export

Sources: U.S. Department of Energy: Geothermal electricity generation

Heat rejection

Air-cooled condenser

The exhaust vapor condenses back to liquid.

How it works

Finned tube banks transfer waste heat from the closed working-fluid circuit to ambient air.

Why it matters

Hot ambient conditions change the heat-rejection capability.

Connected equipment

Working-fluid receiver

Sources: Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Heat rejection

Condenser fans

Fans move ambient air through the fin banks.

How it works

Electric motors maintain airflow across the condenser; their energy is an auxiliary plant load.

Why it matters

Cooling performance and fan consumption affect net export.

Connected equipment

Air-cooled condenser

Sources: Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Working fluid

Working-fluid receiver

Condensed liquid collects before being pumped.

How it works

The small receiver represents the condenser liquid outlet and pump supply volume.

Why it matters

The pump needs a suitable liquid inlet condition.

Connected equipment

Working-fluid pump

Sources: Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Working fluid

Working-fluid pump

The pump returns liquid to the heat exchangers.

How it works

It raises secondary-fluid pressure and feeds the preheater, completing the closed cycle.

Why it matters

Pump consumption must be deducted when assessing net plant output.

Connected equipment

Preheater

Sources: Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Resource

Reinjection pump

Cooled brine is sent toward the injection well.

How it works

The selected pumped return supports reinjection after heat extraction.

Why it matters

Pressure requirements and reservoir response determine pumping needs.

Connected equipment

Injection well

Sources: Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Resource

Injection well

Geothermal fluid returns below ground.

How it works

The isolated return well directs cooled brine into the reservoir, separate from the working-fluid loop.

Why it matters

Well placement and reservoir management influence long-term performance.

Connected equipment

Geothermal reservoir

Sources: U.S. Department of Energy: Geothermal electricity generation · U.S. Department of Energy: Geothermal environmental analysis

Grid

Transformer & export

Electricity leaves through the plant grid interface.

How it works

A step-up transformer, protected switching and an outgoing feeder represent net plant export.

Why it matters

Gross output and export differ because equipment consumes power and incurs losses.

Sources: U.S. Department of Energy: Geothermal electricity generation · U.S. Energy Information Administration: Measuring electricity

Controls

Process monitoring

Instrumentation supervises the two fluid circuits.

How it works

Controls receive temperature, pressure and flow information and command pumps and cooling. Connections carry control signals.

Why it matters

Well and plant monitoring support reliable operation and resource management.

Connected equipment

Production pump & wellhead · Working-fluid pump · Reinjection pump · Condenser fans

Sources: U.S. Department of Energy: Geothermal environmental analysis · Ormat Technologies, Q1 2025 presentation: Air-cooled binary plant schematic, slide 44

Primary sources

  1. Geothermal electricity generation — U.S. Department of Energy
    Checked 2026-10-11
  2. Geothermal power plants — U.S. Energy Information Administration
    Checked 2026-10-11
  3. Geothermal environmental analysis — U.S. Department of Energy
    Checked 2026-10-11
  4. Air-cooled binary plant schematic, slide 44 — Ormat Technologies, Q1 2025 presentation
    Checked 2026-10-11
  5. Measuring electricity — U.S. Energy Information Administration
    Checked 2026-10-11

Nuclear

Nuclear

Fission heats a sealed primary circuit. A steam generator transfers that heat into a separate turbine cycle; a third water path removes condenser heat.

Explore this model ↗

The arrangement

Conventional PWR teaching arrangement with one representative primary loop and once-through condenser cooling. Real plants vary in loop count, safety systems and cooling method. Cutaways omit redundancy and detailed protection systems. Fuel continues to produce decay heat after shutdown, so heat removal must continue.

Input
Uranium fuel releases fission heat in the core.
Conversion
Primary water transfers heat across steam-generator tubes; secondary steam drives a turbine and generator.
Output
AC electricity, rejected heat and used fuel requiring managed storage.
Dispatch
Sustained generation with planned refueling and maintenance outages; plant-specific operating limits govern maneuvering.
Operating constraints
Cooling capability, equipment condition, fuel cycle and licensed operating requirements.
Grid interface
Generator output feeds a transformer; station service and dependable offsite power remain part of the plant.

Development considerations

  • Establish the ultimate heat sink and intake/outfall conditions.
  • Evaluate site hazards, construction access and nuclear licensing.
  • Plan fuel handling, used-fuel storage and long-term responsibilities.
  • Coordinate generator interconnection and offsite electrical supply.

Reading the specifications

Architecture · PWR
Pressurized primary coolant and separate secondary steam; thermal power differs from electrical output.

Export boundary · Net electrical
Generator output less station auxiliaries; grid delivery also depends on intervening losses. No plant rating is implied.

Model scope · Representative
Opened equipment and compressed distances explain connections; dimensions are not construction dimensions.

Nuclear island

Containment structure

A protective enclosure around the reactor system.

How it works

The front half is removed to reveal equipment that normally sits inside the containment boundary.

Why it matters

The teaching section is not an enclosure or safety design.

Sources: U.S. Department of Energy: How does a nuclear reactor work?

Primary circuit

Reactor vessel and core

Fuel releases heat to pressurized water.

How it works

Exposed fuel assemblies sit inside the opened vessel; primary water remains liquid during normal operation.

Why it matters

Reactor thermal power is not the electrical output.

Connected equipment

Steam generator

Sources: U.S. Department of Energy: How does a nuclear reactor work?

Nuclear island

Control rods and drives

Control neutron absorption in the core.

How it works

Rod insertion changes the fission reaction; this is a control relationship to the core.

Why it matters

Stopping the sustained chain reaction does not stop decay heat; cooling is still required after shutdown.

Connected equipment

Reactor vessel and core

Sources: U.S. Department of Energy: How does a nuclear reactor work? · U.S. Department of Energy: Nuclear fuel cycle: wet storage

Primary circuit

Pressurizer

Maintains pressure in the primary system.

How it works

A branch connects this vessel to the primary coolant circuit.

Why it matters

It is not a series step carrying the full reactor coolant flow.

Connected equipment

Reactor vessel and core

Sources: U.S. Department of Energy: How does a nuclear reactor work?

Primary circuit

Reactor coolant pump

Circulates primary water.

How it works

The return leg carries water from the steam generator back to the vessel.

Why it matters

Pumping and heat removal require dependable support systems.

Connected equipment

Reactor vessel and core

Sources: U.S. Department of Energy: How does a nuclear reactor work?

Heat transfer

Steam generator

Transfers heat without mixing the two fluids.

How it works

An opened shell exposes U-tubes joining separate lower primary headers. Feedwater and steam use shell-side ports above the tube sheet.

Why it matters

The tube boundary separates the reactor coolant from the turbine cycle.

Connected equipment

Reactor coolant pump · Steam turbine

Sources: U.S. Department of Energy: How does a nuclear reactor work?

Steam cycle

Steam turbine

Expands steam to produce shaft work.

How it works

The opened lower casing reveals blade stages, with exhaust routed to the condenser.

Why it matters

Steam conditions and condenser performance affect output.

Connected equipment

Generator · Surface condenser

Sources: U.S. Department of Energy: How does a nuclear reactor work? · U.S. Energy Information Administration: Cooling systems that reuse water

Electrical

Generator

Converts shaft rotation into AC electricity.

How it works

The turbine shaft drives the generator rotor.

Why it matters

Generator output is measured before station auxiliaries.

Connected equipment

Generator transformer

Sources: U.S. Department of Energy: How does a nuclear reactor work? · U.S. Energy Information Administration: Net generation definition

Steam cycle

Surface condenser

Condenses turbine exhaust into reusable water.

How it works

Cooling water passes through a separate tube path; heat crosses its walls.

Why it matters

Cooling water does not become reactor coolant.

Connected equipment

Condensate and feedwater train · Cooling-water outfall

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Steam cycle

Condensate and feedwater train

Returns water to the steam generator.

How it works

Pumps and simplified conditioning equipment close the secondary loop.

Why it matters

Real trains include additional heaters, valves and chemistry control.

Connected equipment

Steam generator

Sources: U.S. Department of Energy: How does a nuclear reactor work?

Heat rejection

Cooling-water intake and pumps

Supplies once-through condenser cooling.

How it works

Screened water is pumped from the source through the condenser tube side.

Why it matters

Withdrawal, source temperature and intake ecology are site constraints.

Connected equipment

Surface condenser

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Heat rejection

Cooling-water outfall

Returns warmed cooling water to its source.

How it works

This is the end of the selected once-through path.

Why it matters

Other sites use recirculating cooling; thermal discharge needs site review.

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Electrical

Generator transformer

Connects generator output to the grid.

How it works

A transformer changes voltage for the external electrical system.

Why it matters

Interconnection and station-service boundaries determine deliverable output.

Sources: U.S. Energy Information Administration: Net generation definition

Support

Emergency electrical supply

Represents backup electrical support.

How it works

The cable indicates support to pool cooling, not a complete safety-power design.

Why it matters

The model does not establish redundancy or accident capability.

Connected equipment

Pool cooling equipment

Sources: U.S. Department of Energy: Nuclear fuel cycle: wet storage

Fuel management

Used-fuel pool

Provides shielding and cooling for removed fuel.

How it works

Assemblies remain underwater in an adjacent service area.

Why it matters

Fuel management continues after removal from the reactor.

Connected equipment

Pool cooling equipment

Sources: U.S. Department of Energy: Nuclear fuel cycle: wet storage

Fuel management

Pool cooling equipment

Removes heat from the fuel-storage pool.

How it works

A separate service loop returns cooled water to the pool.

Why it matters

This loop is not connected to the condenser-water pipe.

Connected equipment

Used-fuel pool

Sources: U.S. Department of Energy: Nuclear fuel cycle: wet storage

Primary sources

  1. How does a nuclear reactor work? — U.S. Department of Energy
    Checked 2026-10-11
  2. Cooling systems that reuse water — U.S. Energy Information Administration
    Checked 2026-10-11
  3. Nuclear fuel cycle: wet storage — U.S. Department of Energy
    Checked 2026-10-11
  4. Net generation definition — U.S. Energy Information Administration
    Checked 2026-10-11

Fossil fuels

Combined-cycle gas

The gas turbine generates electricity first. Its hot exhaust passes directly through a heat recovery steam generator, supplying a second turbine cycle.

Explore this model ↗

The arrangement

A 1×1 multi-shaft teaching block with a horizontal HRSG and recirculating condenser cooling. A single steam-pressure path stands in for more detailed pressure and reheat arrangements; duct firing and bypass are omitted.

Input
Natural gas and filtered combustion air; makeup water supports the steam and cooling systems.
Conversion
Gas expansion drives one generator; exhaust heat makes steam for another.
Output
AC electricity from two generators, exhaust gas and rejected condenser heat.
Dispatch
Can serve sustained and intermediate demand; starts and ramps depend on both gas and steam equipment.
Operating constraints
Fuel delivery, ambient conditions, steam-system thermal limits, cooling and emissions constraints.
Grid interface
Both generator outputs reach the grid interface after station-service consumption.

Development considerations

  • Secure gas delivery capacity and pressure at the intended duty.
  • Select condenser cooling against water availability and site conditions.
  • Plan HRSG module transport, heavy lifts and maintenance access.
  • Coordinate air emissions, acoustic treatment and grid interconnection.

Reading the specifications

Configuration · 1 × 1
One gas turbine and one steam turbine, each with a generator. Other configurations are common.

Export boundary · Net electrical
Generator output less station auxiliaries; grid delivery also depends on intervening losses. No plant rating is implied.

Model scope · Representative
Opened equipment and compressed distances explain connections; dimensions are not construction dimensions.

Air and fuel

Air filter house

Filters incoming combustion air.

How it works

Raised filter banks feed the inlet duct.

Why it matters

Inlet cleanliness, icing, pressure losses and noise affect the installation.

Connected equipment

Inlet duct

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Air and fuel

Inlet duct

Guides filtered air into the compressor.

How it works

The bent duct connects the elevated filter house to the axial machine.

Why it matters

Air-path losses affect available output.

Connected equipment

Axial compressor

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Gas cycle

Axial compressor

Raises the pressure of incoming air.

How it works

Rows of rotating blades consume part of the turbine shaft work.

Why it matters

The cutaway shows the compression section before combustion.

Connected equipment

Combustion section

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Gas cycle

Combustion section

Adds fuel energy to the compressed air.

How it works

Burners mix metered fuel and air; hot gases flow toward the turbine.

Why it matters

Fuel specification and emissions controls are equipment-specific.

Connected equipment

Gas turbine expander

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Gas cycle

Gas turbine expander

Extracts shaft work from hot gas.

How it works

Exposed blade rows drive the compressor and generator through the shaft arrangement.

Why it matters

Machinery temperature and ambient conditions constrain output.

Connected equipment

Axial compressor · Gas-turbine generator · Exhaust transition duct

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Electrical

Gas-turbine generator

Converts the gas turbine shaft work to electricity.

How it works

An axial coupling connects the generator at the inlet end of the train.

Why it matters

Gross generation still supplies station auxiliaries.

Connected equipment

Generator transformer

Sources: U.S. Energy Information Administration: Net generation definition · U.S. Energy Information Administration: Combined-cycle plant configurations

Air and fuel

Fuel conditioning and metering

Regulates gas supplied to the combustor.

How it works

Skid vessels and valves represent filtration, regulation and fuel control.

Why it matters

Pipeline pressure, gas quality and delivery capacity require project checks.

Connected equipment

Combustion section

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Heat recovery

Exhaust transition duct

Carries hot turbine exhaust to the HRSG.

How it works

The wide connected duct conveys gas, not steam.

Why it matters

This physical heat connection creates the combined cycle.

Connected equipment

Heat recovery steam generator

Sources: U.S. Energy Information Administration: Combined-cycle plant configurations

Heat recovery

Heat recovery steam generator

Uses exhaust heat to raise steam.

How it works

An opened wall exposes tube banks; water and steam stay inside their own circuit.

Why it matters

Pressure levels and firing options vary by project.

Connected equipment

HRSG outlet and stack · Steam turbine

Sources: GE Vernova: Heat recovery steam generators

Exhaust

HRSG outlet and stack

Discharges cooled combustion exhaust.

How it works

Gas reaches this outlet only after crossing HRSG heat-transfer banks.

Why it matters

Emissions treatment and monitoring are site-specific.

Sources: GE Vernova: Heat recovery steam generators

Steam cycle

Steam turbine

Converts recovered heat into extra shaft work.

How it works

Steam expands through exposed stages and then enters the condenser.

Why it matters

The steam plant adds equipment and operating constraints.

Connected equipment

Steam-turbine generator · Steam condenser

Sources: U.S. Energy Information Administration: Combined-cycle plant configurations

Electrical

Steam-turbine generator

Produces electricity from the steam shaft.

How it works

This generator is separate from the gas-turbine generator.

Why it matters

A shared-shaft layout would arrange this equipment differently.

Connected equipment

Generator transformer

Sources: U.S. Energy Information Administration: Combined-cycle plant configurations

Steam cycle

Steam condenser

Returns turbine exhaust steam to liquid.

How it works

Separate cooling water removes heat across the tube walls.

Why it matters

Cooling performance influences the steam cycle.

Connected equipment

Feedwater pumps and treatment · Mechanical-draft cooling cells

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Steam cycle

Feedwater pumps and treatment

Returns conditioned water to the HRSG.

How it works

The petrol pipe closes the water/steam loop.

Why it matters

Water chemistry and pump power are part of plant operation.

Connected equipment

Heat recovery steam generator

Sources: GE Vernova: Heat recovery steam generators · U.S. Energy Information Administration: Net generation definition

Heat rejection

Mechanical-draft cooling cells

Rejects heat from circulating condenser water.

How it works

Fans move air through the cells; cooled water returns to the condenser.

Why it matters

Recirculation reduces withdrawal but requires makeup water.

Connected equipment

Steam condenser

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Support

Makeup-water treatment

Supplies conditioned makeup water.

How it works

The tank and skid support the selected cooling-water system.

Why it matters

Water quality, consumption and blowdown need a site-specific balance.

Connected equipment

Mechanical-draft cooling cells

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Electrical

Generator transformer

Represents the plant grid interface.

How it works

Both generator circuits reach the export equipment.

Why it matters

Package ratings and net station export use different boundaries.

Sources: U.S. Energy Information Administration: Net generation definition

Support

Plant controls and station service

Coordinates the gas and steam plant.

How it works

Control relationships supervise fuel and feedwater equipment.

Why it matters

Thermal equipment must operate as an integrated block.

Connected equipment

Fuel conditioning and metering · Feedwater pumps and treatment

Sources: GE Vernova: Heat recovery steam generators

Primary sources

  1. Combined-cycle plant configurations — U.S. Energy Information Administration
    Checked 2026-10-11
  2. Heat recovery steam generators — GE Vernova
    Checked 2026-10-11
  3. Natural gas generation by technology — U.S. Energy Information Administration
    Checked 2026-10-11
  4. LM6000 aeroderivative gas turbine — GE Vernova
    Checked 2026-10-11
  5. Cooling systems that reuse water — U.S. Energy Information Administration
    Checked 2026-10-11
  6. Net generation definition — U.S. Energy Information Administration
    Checked 2026-10-11

Fossil fuels

Simple-cycle gas

A gas turbine converts combustion energy directly into shaft power. Its exhaust passes through silencing equipment to the stack, with no steam power cycle.

Explore this model ↗

The arrangement

A compact aeroderivative teaching package with opened axial machinery and lifted enclosure roof. Spool and coupling geometry are schematic; this is not an exact OEM sectional drawing or a claim of black-start capability.

Input
Metered fuel and filtered combustion air.
Conversion
Compression, combustion and expansion produce shaft work for the generator.
Output
AC electricity and hot exhaust; no second steam cycle is shown.
Dispatch
Often used for peak demand and flexible support; actual duty is market- and machine-specific.
Operating constraints
Ambient derating, fuel availability, emissions limits, acoustic treatment and maintenance.
Grid interface
Generator output feeds the transformer; starting and auxiliary loads remain within the station balance.

Development considerations

  • Verify fuel delivery pressure and available capacity.
  • Assess ambient temperature, inlet filtration and icing conditions.
  • Plan noise attenuation, exhaust placement and emissions controls.
  • Reserve access for engine-module replacement and grid equipment.

Reading the specifications

Power cycle · Gas only
There is no HRSG, steam turbine or power-cycle condenser in this arrangement.

Export boundary · Net electrical
Generator output less station auxiliaries; grid delivery also depends on intervening losses. No plant rating is implied.

Model scope · Representative
Opened equipment and compressed distances explain connections; dimensions are not construction dimensions.

Air and fuel

Air filter house

Filters incoming combustion air.

How it works

Raised filter banks feed the inlet duct.

Why it matters

Inlet cleanliness, icing, pressure losses and noise affect the installation.

Connected equipment

Inlet duct

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Air and fuel

Inlet duct

Guides filtered air into the compressor.

How it works

The bent duct connects the elevated filter house to the axial machine.

Why it matters

Air-path losses affect available output.

Connected equipment

Axial compressor

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Gas cycle

Axial compressor

Raises the pressure of incoming air.

How it works

Rows of rotating blades consume part of the turbine shaft work.

Why it matters

The cutaway shows the compression section before combustion.

Connected equipment

Combustion section

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Gas cycle

Combustion section

Adds fuel energy to the compressed air.

How it works

Burners mix metered fuel and air; hot gases flow toward the turbine.

Why it matters

Fuel specification and emissions controls are equipment-specific.

Connected equipment

Gas turbine expander

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Gas cycle

Gas turbine expander

Extracts shaft work from hot gas.

How it works

Exposed blade rows drive the compressor and generator through the shaft arrangement.

Why it matters

Machinery temperature and ambient conditions constrain output.

Connected equipment

Axial compressor · Gas-turbine generator · Exhaust diffuser

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Electrical

Gas-turbine generator

Converts the gas turbine shaft work to electricity.

How it works

An axial coupling connects the generator at the inlet end of the train.

Why it matters

Gross generation still supplies station auxiliaries.

Connected equipment

Generator transformer

Sources: U.S. Energy Information Administration: Net generation definition · U.S. Energy Information Administration: Combined-cycle plant configurations

Air and fuel

Fuel conditioning and metering

Regulates gas supplied to the combustor.

How it works

Skid vessels and valves represent filtration, regulation and fuel control.

Why it matters

Pipeline pressure, gas quality and delivery capacity require project checks.

Connected equipment

Combustion section

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Exhaust

Exhaust diffuser

Guides turbine discharge toward the silencer.

How it works

The widening outlet receives the gas leaving the turbine.

Why it matters

The exhaust path is a significant source of heat and sound.

Connected equipment

Exhaust silencer

Sources: U.S. Energy Information Administration: Combined-cycle plant configurations · GE Vernova: LM6000 aeroderivative gas turbine

Exhaust

Exhaust silencer

Reduces exhaust-path noise.

How it works

Opened side panels expose a schematic bank of acoustic splitters.

Why it matters

Acoustic design and pressure loss are project-specific.

Connected equipment

Exhaust stack

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Exhaust

Exhaust stack

Discharges turbine exhaust to atmosphere.

How it works

No exhaust heat is routed into a steam-generating boiler.

Why it matters

Emissions treatment requirements depend on the installation.

Connected equipment

Exhaust monitoring

Sources: U.S. Energy Information Administration: Combined-cycle plant configurations

Support

Lubrication skid

Supports bearings and rotating machinery.

How it works

Small service lines lead from a tank and pump toward the turbine bearings.

Why it matters

Auxiliary power and maintenance affect station operation.

Connected equipment

Gas turbine expander

Sources: GE Vernova: LM6000 aeroderivative gas turbine · U.S. Energy Information Administration: Net generation definition

Support

Starting and auxiliary package

Represents equipment needed to start the train.

How it works

Auxiliary electrical equipment supplies the start process.

Why it matters

Rapid startup does not establish independent black-start capability.

Connected equipment

Gas turbine expander

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Support

Ventilated package enclosure

Provides weather and acoustic enclosure functions.

How it works

The roof is raised so internal machinery stays visible.

Why it matters

Access, ventilation and noise control shape the package layout.

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Support

Exhaust monitoring

Samples or measures the exhaust condition.

How it works

A small line connects the stack to the monitor cabinet; this is a measurement path.

Why it matters

Monitoring supports the site operating permit.

Connected equipment

Turbine controls

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Support

Turbine controls

Coordinates fuel, starting and protective functions.

How it works

Control connections supervise equipment rather than carry generation output.

Why it matters

Plant-specific control and protection design is outside this model.

Connected equipment

Fuel conditioning and metering · Starting and auxiliary package

Sources: GE Vernova: LM6000 aeroderivative gas turbine

Electrical

Generator transformer

Connects the package to the grid.

How it works

The dark-green circuit represents electrical output routing.

Why it matters

OEM net package figures can exclude balance-of-plant consumption.

Sources: GE Vernova: LM6000 aeroderivative gas turbine · U.S. Energy Information Administration: Net generation definition

Primary sources

  1. LM6000 aeroderivative gas turbine — GE Vernova
    Checked 2026-10-11
  2. Combined-cycle plant configurations — U.S. Energy Information Administration
    Checked 2026-10-11
  3. Natural gas generation by technology — U.S. Energy Information Administration
    Checked 2026-10-11
  4. Net generation definition — U.S. Energy Information Administration
    Checked 2026-10-11

Fossil fuels

Coal

Prepared coal burns in a water-tube furnace. Steam drives the turbine while a separate flue-gas treatment train and solids-handling system manage combustion by-products.

Explore this model ↗

The arrangement

Representative pulverized-coal steam unit informed by NETL process diagrams, with SCR, particulate collection and wet desulfurization. Gallatin provides an operating example of these functions; this is not its as-built layout. Steam pressure stages and reheat are simplified.

Input
Coal, combustion air, treated water and emissions-control reagents.
Conversion
Boiler heat produces steam, which expands through a turbine connected to a generator.
Output
AC electricity, condenser heat, combustion exhaust, ash and desulfurization residue.
Dispatch
Dispatchable steam generation; cycling behavior depends on the unit and equipment condition.
Operating constraints
Fuel properties, steam-system thermal limits, cooling and environmental-control availability.
Grid interface
Generator output reaches the transformer; fans, pumps, mills and treatment systems consume station power.

Development considerations

  • Evaluate coal delivery, stockpile dust and runoff management.
  • Plan ash, reagent and treatment-residue handling over the asset life.
  • Assess cooling-water access and thermal discharge conditions.
  • Review emissions constraints, asset condition and grid access together.

Reading the specifications

Fuel preparation · Pulverized coal
This selected architecture uses mills and burners; other coal conversion arrangements differ.

Export boundary · Net electrical
Generator output less station auxiliaries; grid delivery also depends on intervening losses. No plant rating is implied.

Model scope · Representative
Opened equipment and compressed distances explain connections; dimensions are not construction dimensions.

Fuel

Coal receiving and conveyor

Moves solid fuel from storage toward the boiler.

How it works

The inclined belt feeds the elevated bunker.

Why it matters

Delivery routes, dust and runoff influence the site.

Connected equipment

Coal bunker

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory · U.S. Energy Information Administration: Coal and the environment

Fuel

Coal bunker

Provides a controlled intermediate fuel supply.

How it works

A hopper discharges coal toward the pulverizer.

Why it matters

Storage and feed reliability support continuous firing.

Connected equipment

Coal pulverizer

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Fuel

Coal pulverizer

Prepares coal for suspension firing.

How it works

The mill supplies fine coal and carrier air to the burners.

Why it matters

Fuel properties influence mill and furnace performance.

Connected equipment

Boiler and furnace

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Steam generation

Boiler and furnace

Transfers combustion heat into the steam circuit.

How it works

The open face reveals the furnace, waterwall tubes and suspended heat-transfer banks.

Why it matters

The boiler, rather than the coal pile, creates the steam driving the turbine.

Connected equipment

Steam turbine · Selective catalytic reduction · Bottom-ash and fly-ash handling

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Combustion

Combustion air and air preheater

Supplies air and recovers some flue-gas heat.

How it works

Fans supply the air side; a separate gas passage runs from SCR through the preheater to particulate collection.

Why it matters

Air and flue-gas paths are separate inside the exchanger.

Connected equipment

Boiler and furnace · Particulate collector

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Steam cycle

Steam turbine

Converts steam energy into shaft work.

How it works

Exposed blade stages drive the generator; exhaust enters the condenser.

Why it matters

Detailed pressure stages and reheat are compressed in this model.

Connected equipment

Generator · Steam condenser

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Electrical

Generator

Converts turbine rotation to electricity.

How it works

A straight shaft couples the turbine and generator.

Why it matters

Generator output exceeds net station export by station-service consumption.

Connected equipment

Generator transformer

Sources: U.S. Energy Information Administration: Net generation definition

Steam cycle

Steam condenser

Condenses turbine steam for reuse.

How it works

A separate circulating-water tube path carries heat away.

Why it matters

Heat rejection is a major site requirement.

Connected equipment

Feedwater train · Cooling-water cells

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Steam cycle

Feedwater train

Returns water to the boiler.

How it works

Pumps and simplified conditioning equipment close the steam cycle.

Why it matters

Water chemistry and pump energy affect reliable operation.

Connected equipment

Boiler and furnace

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Heat rejection

Cooling-water cells

Rejects heat from the condenser loop.

How it works

Mechanical-draft cells cool circulating water before its return.

Why it matters

Makeup water and operating conditions affect the plant.

Connected equipment

Steam condenser

Sources: U.S. Energy Information Administration: Cooling systems that reuse water

Emissions

Selective catalytic reduction

Treats nitrogen oxides in the flue gas.

How it works

The opened housing exposes schematic catalyst layers.

Why it matters

Reagent and catalyst performance are part of the operating system.

Connected equipment

Combustion air and air preheater

Sources: Tennessee Valley Authority: Gallatin Fossil Plant · DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Emissions

Particulate collector

Captures fly ash carried by flue gas.

How it works

Filter elements sit above collection hoppers in this selected baghouse arrangement.

Why it matters

Collected solids still need controlled handling.

Connected equipment

Induced-draft fan · Bottom-ash and fly-ash handling

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory

Emissions

Induced-draft fan

Moves gas through the treatment path.

How it works

The fan sits downstream of particulate collection and upstream of the wet scrubber.

Why it matters

Fan electricity contributes to auxiliary consumption.

Connected equipment

Wet desulfurization and reagent system

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory · U.S. Energy Information Administration: Net generation definition

Emissions

Wet desulfurization and reagent system

Removes sulfur dioxide from the gas.

How it works

An absorber uses reagent slurry; a separate residue route represents gypsum or treatment solids.

Why it matters

This equipment does not capture carbon dioxide.

Connected equipment

Treated-flue-gas stack

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory · Tennessee Valley Authority: Gallatin Fossil Plant · U.S. Energy Information Administration: Coal and the environment

Emissions

Treated-flue-gas stack

Discharges the remaining combustion gas.

How it works

The connected duct receives gas after the wet absorber.

Why it matters

Air treatment does not make coal combustion carbon-free.

Sources: U.S. Energy Information Administration: Coal and the environment

Solids

Bottom-ash and fly-ash handling

Collects combustion solids for managed handling.

How it works

The furnace-bottom route and collector route converge on the ash-handling area.

Why it matters

Residue storage, dewatering, reuse or disposal need dedicated planning.

Sources: DOE National Energy Technology Laboratory: Power Plant Flexible Model emissions inventory · Tennessee Valley Authority: Gallatin Fossil Plant

Electrical

Generator transformer

Connects the station to the external grid.

How it works

The electrical route carries generator output toward the transformer.

Why it matters

Net output accounts for mills, fans, pumps and other station loads.

Sources: U.S. Energy Information Administration: Net generation definition

Primary sources

  1. Power Plant Flexible Model emissions inventory — DOE National Energy Technology Laboratory
    Checked 2026-10-11
  2. Gallatin Fossil Plant — Tennessee Valley Authority
    Checked 2026-10-11
  3. Coal and the environment — U.S. Energy Information Administration
    Checked 2026-10-11
  4. Cooling systems that reuse water — U.S. Energy Information Administration
    Checked 2026-10-11
  5. Net generation definition — U.S. Energy Information Administration
    Checked 2026-10-11

Fossil fuels

Diesel generation

A diesel engine converts fuel energy to shaft power, and an alternator converts that rotation to electricity. Fuel, starting, cooling, exhaust and transfer equipment make the generator usable as a facility system.

Explore this model ↗

The arrangement

Representative single engine-alternator standby installation with bulk and day fuel tanks, radiator cooling, an output breaker and an open-transition transfer switch. No utility paralleling is assumed.

Input
Diesel fuel and combustion air; stored electrical energy starts the engine.
Conversion
Combustion drives pistons and the crankshaft; the coupled alternator produces AC.
Output
Electricity to the selected facility bus, plus exhaust and rejected heat.
Dispatch
The controls start and stabilize the set before transfer equipment connects the load.
Operating constraints
Fuel availability, maintenance, emissions permissions, ambient conditions, transient load response and the selected duty rating limit operation.
Grid interface
The illustrated transfer switch selects utility or generator supply. Parallel operation requires a different engineered control and protection arrangement.

Development considerations

  • Select standby, prime or continuous duty using the actual load and operating hours.
  • Plan fuel replenishment, containment, access and quality management.
  • Evaluate exhaust dispersion, noise, heat rejection and permitting for the intended duty.
  • Study starting, load steps, transfer behavior and the supported facility load.

Reading the specifications

Output · kW / MW
Electrical output under a stated rating and site conditions.

Duty · Standby
This selected application supports supply interruptions; it is not a continuous-duty promise.

Autonomy · Site-specific
Usable fuel and consumption at the actual load determine runtime.

Fuel

Bulk fuel tank and containment

The bulk tank holds the site’s fuel inventory.

How it works

A transfer line supplies the smaller day tank; the surrounding bund represents containment.

Why it matters

Tank volume alone does not establish delivered electrical runtime.

Connected equipment

Day tank

Sources: Caterpillar: C175-20 diesel generator set

Fuel

Day tank

A local tank provides fuel near the engine.

How it works

Transfer controls maintain its working level from bulk storage.

Why it matters

Fuel level and transfer reliability affect available standby service.

Connected equipment

Fuel filters and supply

Sources: Caterpillar: C175-20 diesel generator set

Fuel

Fuel filters and supply

Filters and supply equipment condition fuel before injection.

How it works

The supply path connects the day tank to the engine; excess fuel returns in the selected illustration.

Why it matters

Clean fuel and maintainable components support starting and operation.

Connected equipment

Engine block and cylinders · Day tank

Sources: Caterpillar: C175-20 diesel generator set

Conversion

Engine block and cylinders

Combustion turns fuel energy into mechanical work.

How it works

The exposed cylinder banks sit above the crankshaft.

Why it matters

Engine limits, site conditions and load response constrain power.

Connected equipment

Crankshaft and coupling · Coolant supply and return · Exhaust manifold and silencer

Sources: Caterpillar: C175-20 diesel generator set · Caterpillar: A Holistic View On Generator Set Ratings

Combustion air

Air filter and turbocharger

The intake supplies filtered air for combustion.

How it works

The compressor receives shaft work from the exhaust-driven turbine; filtered intake air and exhaust remain separate.

Why it matters

Air restriction and ambient conditions affect performance.

Connected equipment

Engine block and cylinders

Sources: Caterpillar: C175-20 diesel generator set · Caterpillar: Turbocharger turbine and compressor operation

Conversion

Crankshaft and coupling

The crankshaft carries engine torque to the alternator.

How it works

A direct mechanical coupling links the two machines on a common skid.

Why it matters

Mechanical alignment and torsional behavior matter to the complete set.

Connected equipment

Alternator rotor and stator

Sources: Caterpillar: C175-20 diesel generator set

Conversion

Alternator rotor and stator

The alternator converts rotation into AC power.

How it works

The cutaway shows a central rotor inside the winding-bearing stator.

Why it matters

Electrical and thermal ratings must suit the load and duty.

Connected equipment

Generator output breaker

Sources: Caterpillar: A Holistic View On Generator Set Ratings

Heat rejection

Radiator and fan

The radiator releases coolant heat to ambient air.

How it works

A fan moves air through the heat-exchanger fins.

Why it matters

Restricted airflow or high ambient temperature can reduce available output.

Connected equipment

Coolant supply and return

Sources: Caterpillar: C175-20 diesel generator set

Heat rejection

Coolant supply and return

A closed loop transports heat away from the engine.

How it works

Two connected pipes run between the engine and radiator.

Why it matters

Cooling is a continuous operating requirement, not an optional accessory.

Connected equipment

Radiator and fan · Engine block and cylinders

Sources: Caterpillar: C175-20 diesel generator set

Exhaust

Exhaust manifold and silencer

Exhaust carries combustion products out of the installation.

How it works

Manifolds feed the turbocharger turbine, then the silencer and stack. The turbine drives the intake compressor mechanically without mixing the gas streams.

Why it matters

Backpressure, heat, emissions and noise require engineering review.

Connected equipment

Air filter and turbocharger

Sources: Caterpillar: Generator ancillary equipment · Caterpillar: Turbocharger turbine and compressor operation

Starting

Starting battery and motor

Stored electrical energy cranks the engine.

How it works

A battery, charger and starter support the starting sequence.

Why it matters

A generator with fuel still needs a dependable starting system.

Connected equipment

Engine block and cylinders · Governor and voltage regulator

Sources: Caterpillar: C175-20 diesel generator set

Controls

Governor and voltage regulator

Controls regulate engine speed and alternator voltage.

How it works

Signals supervise the engine, excitation and output protection.

Why it matters

Standby, prime and continuous ratings have different operating conditions.

Connected equipment

Engine block and cylinders · Alternator rotor and stator · Generator output breaker

Sources: Caterpillar: A Holistic View On Generator Set Ratings

Electrical output

Generator output breaker

The output breaker connects and protects the generator circuit.

How it works

Alternator conductors feed the breaker before transfer equipment.

Why it matters

Protection must coordinate with the generator’s fault contribution and facility distribution.

Connected equipment

Utility / generator transfer

Sources: Occupational Safety and Health Administration: Electric power glossary

Electrical output

Utility / generator transfer

The selected switch connects one source to the facility bus.

How it works

Two incoming paths reach a common load path; this open-transition arrangement does not parallel them.

Why it matters

Transfer behavior determines the interruption seen by connected loads.

Connected equipment

Facility load connection · Governor and voltage regulator

Sources: Cummins: Specifying the Right Transfer Switch

Electrical output

Facility load connection

The outgoing bus carries the selected source to facility distribution.

How it works

It marks the downstream boundary of this generator installation.

Why it matters

Only the designed connected load is supported; the model promises no universal capacity.

Connected equipment

Utility / generator transfer

Sources: Occupational Safety and Health Administration: Electric power glossary

Structure

Machine hall and common skid

The opened hall reveals the engine-alternator and service access.

How it works

A common base carries the coupled machines; an open roof exposes auxiliaries.

Why it matters

Access, noise control and structural support shape the installation.

Connected equipment

Engine block and cylinders · Alternator rotor and stator

Sources: Caterpillar: C175-20 diesel generator set

Primary sources

  1. C175-20 diesel generator set — Caterpillar
    Checked 2026-10-11
  2. A Holistic View On Generator Set Ratings — Caterpillar
    Checked 2026-10-11
  3. Generator ancillary equipment — Caterpillar
    Checked 2026-10-11
  4. Turbocharger turbine and compressor operation — Caterpillar
    Checked 2026-10-11
  5. Specifying the Right Transfer Switch — Cummins
    Checked 2026-10-11
  6. Electric power glossary — Occupational Safety and Health Administration
    Checked 2026-10-11

Storage

Battery storage

A utility battery stores electrical energy chemically and returns it through a power conversion system. This opened enclosure separates the battery, power electronics, cooling and protection.

Explore this model ↗

The arrangement

Representative AC-coupled lithium-ion BESS with modular racks, a shared DC collection system, bidirectional PCS and a transformer at the grid interface. Equipment counts and enclosure layout are illustrative. Electrical connections are bidirectional: charging reverses the discharge route; the two modes are alternatives.

Input
AC electricity charges the battery through the transformer and PCS.
Conversion
The PCS converts AC to DC while charging and DC to AC while discharging.
Output
Controlled AC power at the interconnection; usable energy is finite.
Dispatch
The EMS requests power; BMS and PCS limits govern what can be delivered.
Operating constraints
SOC window, temperature, degradation, conversion losses and auxiliary demand limit usable energy. A minimum SOC is not automatically a backup reserve.
Grid interface
Interconnection protection and metering are required. Islanding and black start depend on the selected design and agreement.

Development considerations

  • Define the service: energy shifting, grid support or a specifically engineered backup duty.
  • Specify both deliverable MW and usable MWh at the contractual measurement point.
  • Coordinate enclosure spacing, access, thermal design and emergency response with the selected product and site.
  • Establish SOC policy, degradation allowance, augmentation and operating responsibilities.

Reading the specifications

Power · MW
Charge/discharge rate at a stated measurement point.

Energy · MWh
Usable stored energy depends on SOC limits and operating conditions.

Duration · MWh ÷ MW
An approximate discharge duration at a specified steady output, not a universal runtime.

Storage

Cell modules

Modules contain the lithium-ion cells that store energy.

How it works

Cells are interconnected within modules; the open rack face shows repeated trays.

Why it matters

Cell condition determines usable capacity and operating limits.

Connected equipment

Rack strings

Sources: Sandia National Laboratories: Energy Storage Handbook: management systems

Storage

Rack strings

Racks assemble modules into electrical strings.

How it works

String connections collect module power and route it toward the DC bus.

Why it matters

A rack can be isolated without representing the whole site as one cell.

Connected equipment

DC bus and disconnect · Cell modules · Battery management system

Sources: Sandia National Laboratories: Energy Storage Handbook: management systems

Power path

DC bus and disconnect

The DC collection system connects racks to the PCS.

How it works

Bus conductors and isolation/protection devices carry bidirectional current.

Why it matters

DC isolation and fault protection are distinct from AC interconnection protection.

Connected equipment

Bidirectional PCS · Rack strings

Sources: Sandia National Laboratories: Energy Storage Handbook: management systems

Controls

Battery management system

The BMS monitors battery condition and enforces battery limits.

How it works

Voltage, temperature and current measurements support state estimation and protection.

Why it matters

Its limits constrain dispatch even when energy remains.

Connected equipment

Energy management system · Bidirectional PCS

Sources: Sandia National Laboratories: Energy Storage Handbook: management systems

Controls

Energy management system

The EMS schedules the storage plant.

How it works

It sends PCS requests using battery state and the chosen operating policy.

Why it matters

A reserve must be configured explicitly; it is not a fixed property of storage.

Connected equipment

Bidirectional PCS

Sources: Sandia National Laboratories: Energy Storage Handbook: management systems

Conversion

Bidirectional PCS

Power electronics exchange energy between the DC battery and AC system.

How it works

The bridged cabinets form one PCS assembly; its inverter/rectifier stage controls charge or discharge under battery and grid constraints.

Why it matters

Converter power limits differ from the battery energy capacity.

Connected equipment

AC filter and reactor · DC bus and disconnect

Sources: Sandia National Laboratories: Energy Storage Handbook: management systems

Conversion

AC filter and reactor

The converter interface includes electrical filtering.

How it works

Filter components, including inductive reactors, condition the switched output. They are exposed here for inspection and can be integrated inside the PCS.

Why it matters

The selected PCS and interconnection study determine the actual filter design.

Connected equipment

AC switchgear · Bidirectional PCS

Sources: ABB: PCS100 ESS converter filters, pp. 18, 68

Grid interface

AC switchgear

Switchgear collects and protects the PCS AC circuit.

How it works

Breaker equipment connects the converter circuit to the transformer.

Why it matters

The system must coordinate isolation and protection across AC and DC sides.

Connected equipment

Interconnection transformer · AC filter and reactor

Sources: Fluence: Gridstack technical specification

Grid interface

Interconnection transformer

The transformer matches the PCS voltage to the site network.

How it works

Magnetically coupled windings transfer power in either direction.

Why it matters

Voltage and transformer rating are project-specific.

Connected equipment

Meter and interconnection protection · AC switchgear

Sources: Fluence: Gridstack technical specification

Grid interface

Meter and interconnection protection

The interface records imported and exported energy.

How it works

Metering and protection monitor the plant connection.

Why it matters

Delivered energy is assessed at a defined boundary, including applicable losses.

Connected equipment

Interconnection transformer

Sources: U.S. Department of Energy: Battery Energy Storage System Evaluation Method

Thermal systems

Thermal management skid

The cooling unit rejects battery heat.

How it works

This selected illustration uses a closed coolant loop and an air-cooled heat exchanger.

Why it matters

Temperature can constrain power before the battery reaches its energy limit.

Connected equipment

Cooling distribution

Sources: Sandia National Laboratories: Energy Storage Handbook: management systems · Fluence: Gridstack technical specification

Thermal systems

Cooling distribution

Supply and return lines connect the thermal unit to the racks.

How it works

Coolant carries heat away from the battery modules and returns to the skid.

Why it matters

Auxiliary cooling consumes energy and requires service access.

Connected equipment

Thermal management skid · Cell modules

Sources: Fluence: Gridstack technical specification

Protection

Gas and heat detection

Sensors identify abnormal enclosure conditions.

How it works

Detection signals go to the protection controller and plant controls.

Why it matters

Detection reduces response delay; it does not guarantee that thermal runaway cannot occur.

Connected equipment

Energy management system · Enclosure and protection provisions

Sources: Fluence: Gridstack technical specification

Protection

Enclosure and protection provisions

The enclosure incorporates product-specific protective measures.

How it works

The cutaway shows compartment walls, detection mounts and a designated relief panel.

Why it matters

Fire response, ventilation and suppression choices require a site-specific engineered design.

Connected equipment

Gas and heat detection

Sources: Fluence: Gridstack technical specification

Primary sources

  1. Energy Storage Handbook: management systems — Sandia National Laboratories
    Checked 2026-10-11
  2. Battery Energy Storage System Evaluation Method — U.S. Department of Energy
    Checked 2026-10-11
  3. Gridstack technical specification — Fluence
    Checked 2026-10-11
  4. PCS100 ESS converter filters, pp. 18, 68 — ABB
    Checked 2026-10-11

Storage

Pumped storage

Electricity pumps water uphill to store gravitational energy. During discharge, the same water returns through a turbine and drives a generator.

Explore this model ↗

The arrangement

Representative closed-loop, two-reservoir plant with a reversible pump-turbine and vertical motor-generator. The landscape is compressed to reveal the connected hydraulic route; no natural river is depicted. Hydraulic and electrical connections are bidirectional; pumping reverses generating flow rather than occurring simultaneously.

Input
Electricity during pumping; water is moved from the lower reservoir to the upper reservoir.
Conversion
The motor drives the pump on charge. Descending water drives the turbine and generator on discharge.
Output
AC electricity on discharge and water returned to the lower reservoir.
Dispatch
Select pumping, generating or stopped operation according to reservoir and machine limits.
Operating constraints
Working water volume, net head, machine rating and losses determine available power and energy. A full cycle returns less energy than pumping consumed.
Grid interface
The motor-generator imports and exports through the same switchgear and transformer.

Development considerations

  • Assess geology, elevation difference, reservoir sites and conveyance works together.
  • Separate machine MW from usable reservoir energy and evaluate head variation.
  • Study environmental, initial-fill and makeup-water requirements even for closed-loop projects.
  • Coordinate grid studies with pumping demand, generating capability and transition behavior.

Reading the specifications

Power · MW
Machine output or pumping demand in its selected operating mode.

Energy · MWh
Usable gravitational storage depends on volume, net head and losses.

Architecture · Closed loop
No ongoing hydrologic connection to a natural water body in this selected layout.

Water storage

Upper reservoir

Elevated water holds gravitational potential energy.

How it works

Its usable operating range supplies the hydraulic route during generation.

Why it matters

Usable volume and changing head constrain stored energy.

Connected equipment

Upper intake screen

Sources: U.S. Department of Energy: Pumped Storage Hydropower

Water route

Upper intake screen

The intake admits water to the conveyance system.

How it works

A screen excludes large debris before the intake gate.

Why it matters

Hydraulic losses and access affect operation and maintenance.

Connected equipment

Intake gate · Upper reservoir

Sources: U.S. Department of Energy: Types of Hydropower Plants

Water route

Intake gate

The gate isolates the reservoir-side water passage.

How it works

A guided closure occupies the inlet to the penstock.

Why it matters

Waterway isolation is separate from electrical isolation.

Connected equipment

Pressure conduit · Upper intake screen

Sources: U.S. Department of Energy: Types of Hydropower Plants

Water route

Pressure conduit

The penstock connects the high reservoir to the machine.

How it works

It carries pressurized water downhill on discharge and uphill on charge.

Why it matters

Hydraulic design must address pressure, losses and transient loads.

Connected equipment

Machine inlet valve · Intake gate

Sources: U.S. Department of Energy: Types of Hydropower Plants

Water route

Machine inlet valve

The inlet valve isolates the machine water passage.

How it works

A large valve connects the pressure conduit to the spiral casing.

Why it matters

Its role differs from the runner’s energy conversion.

Connected equipment

Spiral casing and guide vanes · Pressure conduit

Sources: U.S. Department of Energy: Types of Hydropower Plants

Conversion

Spiral casing and guide vanes

The casing distributes water around the runner during generation and collects it during pumping.

How it works

Adjustable guide vanes control admission to the runner during generation. Their position during pumping depends on the machine and operating mode.

Why it matters

The opened casing makes the hydraulic-to-mechanical interface visible.

Connected equipment

Reversible pump-turbine · Machine inlet valve

Sources: ANDRITZ Hydro: Pump turbines: guide-vane actuation and variants · U.S. Department of Energy: Microhydropower Handbook: reaction turbines, §4.1.2

Conversion

Reversible pump-turbine

The runner transfers energy between water and the shaft.

How it works

Water drives it during discharge; the motor drives it during pumping.

Why it matters

Operating envelopes and transitions are machine-specific.

Connected equipment

Vertical shaft · Draft tube and lower waterway · Spiral casing and guide vanes

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Conversion

Vertical shaft

A shaft couples the hydraulic and electrical machines.

How it works

Torque passes between the runner below and motor-generator above.

Why it matters

The same mechanical train serves both operating modes.

Connected equipment

Motor-generator · Reversible pump-turbine

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Conversion

Motor-generator

One electrical machine generates or drives the pump.

How it works

It converts shaft power to AC on discharge and AC to shaft power on charge.

Why it matters

Pumping consumes electricity rather than creating a new energy source.

Connected equipment

Machine switchgear · Vertical shaft

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Water route

Draft tube and lower waterway

The lower passage joins the runner and lower basin.

How it works

Water exits here during generation and enters here during pumping.

Why it matters

The two directions use the same connected hydraulic route.

Connected equipment

Lower reservoir · Reversible pump-turbine

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Water storage

Lower reservoir

The lower basin receives water during discharge.

How it works

Pumping withdraws this water and returns it to the upper basin.

Why it matters

Working levels must support both operating modes.

Connected equipment

Draft tube and lower waterway

Sources: U.S. Department of Energy: Pumped Storage Hydropower

Grid interface

Machine switchgear

Switchgear connects and protects the motor-generator.

How it works

The electrical path supports both import and export.

Why it matters

Electrical ratings and operating sequences depend on the selected machine.

Connected equipment

Plant transformer · Motor-generator

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Grid interface

Plant transformer

The transformer matches machine and grid voltages.

How it works

Power passes through it in either operating direction.

Why it matters

There is no universal plant interconnection voltage.

Connected equipment

Bidirectional grid connection · Machine switchgear

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Grid interface

Bidirectional grid connection

The plant imports pumping energy and exports generated energy.

How it works

One connection serves both modes in this illustration.

Why it matters

Charging demand and generating capability both require network studies.

Connected equipment

Plant transformer

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Controls

Governor and unit controls

Unit controls coordinate water flow and electrical operation.

How it works

Control signals supervise the guide vanes, motor-generator and switchgear.

Why it matters

The model describes functions, not an executable operating procedure.

Connected equipment

Spiral casing and guide vanes · Motor-generator · Machine switchgear

Sources: Oak Ridge National Laboratory / DOE: Pumped Storage FAST Commissioning Technical Analysis

Primary sources

  1. Pumped Storage Hydropower — U.S. Department of Energy
    Checked 2026-10-11
  2. Types of Hydropower Plants — U.S. Department of Energy
    Checked 2026-10-11
  3. Pumped Storage FAST Commissioning Technical Analysis — Oak Ridge National Laboratory / DOE
    Checked 2026-10-11
  4. Pump turbines: guide-vane actuation and variants — ANDRITZ Hydro
    Checked 2026-10-11
  5. Microhydropower Handbook: reaction turbines, §4.1.2 — U.S. Department of Energy
    Checked 2026-10-11

Grid

Transmission & utility

The utility network delivers power generated elsewhere. This opened substation shows how a three-phase circuit is switched, measured, protected and transformed before an outgoing feeder reaches a customer boundary.

Explore this model ↗

The arrangement

Representative air-insulated, single incoming circuit, single-bus step-down substation. CTs are in the main current path; PTs and surge arresters are connected as branches. Ownership and voltage levels vary by project.

Input
Three-phase AC from the upstream network.
Conversion
A transformer changes voltage; the site does not generate electricity.
Output
A protected outgoing feeder at the selected customer interface.
Dispatch
Network operators control circuit connectivity and protection settings; customer capacity comes from the service agreement and studies.
Operating constraints
Thermal ratings, voltage limits, fault duty, upstream constraints and outages affect delivery.
Grid interface
Three phases are one circuit here, not three independent feeds. The model claims no reserved capacity or universal service voltage.

Development considerations

  • Confirm the point of connection, ownership boundary and service capacity with the utility.
  • Study available capacity, fault duty, voltage, protection and potential network upgrades.
  • Evaluate actual common-mode exposure before describing feeds as independent.
  • Allow for land, access, equipment lead times, permitting and utility commissioning.

Reading the specifications

Function · Delivery
Switches, protects, meters and transforms power generated elsewhere.

Circuit · 3-phase AC
One illustrative incoming circuit; phases are not independent sources.

Voltage · Project-specific
Both sides of the transformer are selected through network design.

Incoming circuit

Incoming line and gantry

The gantry receives the three phase conductors.

How it works

Each conductor terminates on insulated hardware before entering the yard.

Why it matters

A visible three-phase arrangement represents one circuit.

Connected equipment

Phase insulation

Sources: Occupational Safety and Health Administration: Electric power glossary

Incoming circuit

Phase insulation

Insulators separate live conductors from grounded structures.

How it works

Porcelain-like shed geometry represents outdoor phase insulation.

Why it matters

Electrical clearances and insulation are selected for the installation.

Connected equipment

Disconnecting switch

Sources: Occupational Safety and Health Administration: Electric power glossary

Switching

Disconnecting switch

The disconnector provides an isolation function.

How it works

Three closed blades are shown for the connected operating arrangement.

Why it matters

Do not confuse isolation with a breaker’s fault interruption duty.

Connected equipment

Current transformers

Sources: Hitachi Energy: Disconnecting circuit breaker: two functions

Measurement

Current transformers

CTs provide scaled current measurements.

How it works

The main conductors pass through the illustrated CT apertures; secondary signals go to relays and metering.

Why it matters

Protection depends on suitable measurement performance.

Connected equipment

Three-pole circuit breaker · Protective relays and controls

Sources: Occupational Safety and Health Administration: Electric power glossary

Measurement

Voltage transformers

PTs provide scaled voltage measurements.

How it works

They sense phase voltage through branches from the HV bus.

Why it matters

The sensing branch is not a series power-conversion stage.

Connected equipment

Protective relays and controls · Metering and customer handoff

Sources: Occupational Safety and Health Administration: Electric power glossary

Switching

Three-pole circuit breaker

The circuit breaker interrupts load and fault current within its ratings.

How it works

Three linked pole assemblies connect the line-side circuit to the bus.

Why it matters

Relay commands operate the breaker; disconnectors serve a different function.

Connected equipment

High-side bus

Sources: Occupational Safety and Health Administration: Electric power glossary · Hitachi Energy: Disconnecting circuit breaker: two functions

Protection

Surge arresters

Arresters limit transient overvoltage.

How it works

Each phase has a branch toward the grounding system.

Why it matters

They do not sit in series carrying the normal delivery power.

Connected equipment

Grounding and bonding

Sources: Occupational Safety and Health Administration: Electric power glossary

Power path

High-side bus

A bus joins the incoming circuit and transformer branch.

How it works

Three phase conductors feed the transformer and sensing/protection branches.

Why it matters

This selected single-bus layout does not imply redundancy.

Connected equipment

Voltage transformers · Surge arresters · Step-down transformer

Sources: Occupational Safety and Health Administration: Electric power glossary

Voltage transformation

Step-down transformer

The transformer transfers energy between voltage levels.

How it works

The cutaway exposes a core and paired windings beneath high- and low-side bushings.

Why it matters

Its rating, impedance and voltage ratio come from the project design.

Connected equipment

Low-side bus and feeder breaker · Transformer cooling

Sources: Occupational Safety and Health Administration: Electric power glossary

Heat rejection

Transformer cooling

Radiators transfer transformer losses to the surroundings.

How it works

External panels connect thermally to the transformer tank.

Why it matters

Cooling conditions affect allowable loading.

Connected equipment

Step-down transformer

Sources: Occupational Safety and Health Administration: Electric power glossary

Outgoing circuit

Low-side bus and feeder breaker

The low-side switchgear collects transformer output.

How it works

An enclosed bus and feeder breaker supply the outgoing cable.

Why it matters

Feeder protection coordinates with upstream and customer equipment.

Connected equipment

Outgoing feeder

Sources: Occupational Safety and Health Administration: Electric power glossary

Outgoing circuit

Outgoing feeder

The feeder carries electricity toward the customer.

How it works

Three grouped cables follow an exposed trench route.

Why it matters

Route and utility topology determine real common-mode exposure.

Connected equipment

Metering and customer handoff

Sources: Occupational Safety and Health Administration: Electric power glossary

Customer interface

Metering and customer handoff

The handoff marks the illustrative service boundary.

How it works

A meter cabinet accompanies the outgoing supply connection.

Why it matters

Ownership and commercial delivery terms are project-specific.

Connected equipment

Outgoing feeder

Sources: Occupational Safety and Health Administration: Electric power glossary

Controls

Protective relays and controls

Relays evaluate measurements and command interruption when required.

How it works

CT/PT signals enter the control house; trip signals return to the breaker.

Why it matters

Protection settings and coordination govern selective fault clearing.

Connected equipment

Three-pole circuit breaker

Sources: Occupational Safety and Health Administration: Electric power glossary

Controls

Station battery and charger

Station DC supports protection and breaker controls.

How it works

The local battery and charger feed the trip/control circuits.

Why it matters

This small auxiliary battery is distinct from a grid energy-storage plant.

Connected equipment

Protective relays and controls · Three-pole circuit breaker

Sources: Occupational Safety and Health Administration: Electric power glossary

Protection

Grounding and bonding

A buried grid bonds exposed conductive structures.

How it works

The exposed grid includes representative bonds to the gantry, transformer tank and surge arresters.

Why it matters

The educational cutaway is not a grounding design or safe-work procedure.

Connected equipment

Incoming line and gantry · Step-down transformer · Surge arresters

Sources: Occupational Safety and Health Administration: Electric power glossary

Primary sources

  1. Electric power glossary — Occupational Safety and Health Administration
    Checked 2026-10-11
  2. Disconnecting circuit breaker: two functions — Hitachi Energy
    Checked 2026-10-11